archive-de.com » DE » M » MS2-ENGINEERING.DE

Total: 55

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".

  • the selection of the safety valves up to the development and verification of the alarm matrix We particularly pay attention to the correct integration of the individual test bench into the entire concept of the test field If dangerous combustible atmospheres are possible we will provide you with an explosion prevention document based on a safety analysis after the valid reliability regulation If the existing safety system of your test

    Original URL path: http://ms2-engineering.de/e_engineering_infrasicher.htm (2016-02-12)
    Open archived version from archive



  • many year s standing offers you a reliable solution for your requirements Our main emphasis is programming with labView and labView real time with the following services Development of a software concept Development of requirement specifications Programming Validation and operation

    Original URL path: http://ms2-engineering.de/e_engineering_software.htm (2016-02-12)
    Open archived version from archive


  • test benches e g operating costs maintenance and recycling The several concepts can be compared by trade off analysis The criterias and rankings of the analysis will be adapted to your needs Thus you can determine the right balance between costs and benefits for your requirements Constitutive on the results of the trade off analysis we will gladly support you with a requirement specification Infrastructure safety engineering Safety for humans and our environment is our highest priority Use our experiences and our knowledge to plan and specify your infrastructure to the latest state of the art We integrate safety aspects from the beginning on from the selection of the safety valves up to the development and verification of the alarm matrix We particularly pay attention to the correct integration of the individual test bench into the entire concept of the test field If dangerous combustible atmospheres are possible we will provide you with an explosion prevention document based on a safety analysis after the valid reliability regulation If the existing safety system of your test benches is not sufficient we can offer suggestions for improvement If your test benches or facilities are subject to authorisation or subject to acceptance we

    Original URL path: http://ms2-engineering.de/e_engineering_start.htm (2016-02-12)
    Open archived version from archive


  • of the infrastructure Packaging concepts Requirement definition of the safety engineering Support in preliminary talks with regulatory authority You will be inspired by our innovative concepts which will offer the optimal solution to your requirements based on our tested and highly qualified components and units To you this means robustable and flexible test benches The software is easy to handle and contains a reliable alarm processing You will receive reproductible results with a very high availability of the test bench Constant project and quality management guarantees adherence to your requirements with respect to the test bench the costs and the deadline back Assembly Installation All from one source Our test benches will be delivered completely assembled and tested Supported by our efficient mechanical workshop there are no difficulties which we can not solve Whether you have electrical mechanical or process engineering assemblies and installations you can count on our experiences and abilities Before the shipment all examinations and calibrations will be executed Before the shipment you are welcome to inspect the test bench according to your requirement specification back Commissioning Training Competence and professionalism After installing the test bench on the spot each component will be tested and the electrical and mechanical test acceptance will be accomplished Thereafter the complete test bench will be started under operating conditions and if necessary the software parameters will be adjusted We will instruct your commissioning and maintenance staff in the hardware and software of the test bench in order for you to be able to run the test bench after start up on your own back Service MS2 maintenance service A shutdown of a test bench is expensive To prevent this we offer you a coordinated maintenance concept Uncomplicated and fast Test benches are usually technically very complex Their optimal availability is assured

    Original URL path: http://ms2-engineering.de/e_produkte_start.htm (2016-02-12)
    Open archived version from archive


  • Characteristic determination of flow meters with water Determination of components leakage rates Determination of characteristics of flow meters with gas Continuous and parallel operation of all measurements is possible Interfaces to test devices Liquids Media Flow range Pressure range Temperature range Water 0 1 to 10 m 3 h Water 1 to 6 bara 20 C to 90 C Gas Media Flow range Pressure range Methane nitrogen air 0 01 to 50 Nm 3 h 1 bis 8 bara Control system National Instruments Real Time System Programming LabView back Example 2 Test task Characteristic determination and continuous operation testing of process engineering components and reactors with Different kinds of gases and their mixtures Different liquids Keeping at a moderate temperature of all media up to 280 C with plate heat exchanger of different pressure levels Process control with online analytics FID IR TCD and gas conditioning Interfaces to test devices Liquids Media Flow range Pressure range Temperature range Water combustible liquids 0 01 to 20 kg h 1 to 16 bara 20 C to 280 C Gas Media Flow range Pressure range Temp range Hydrogen CO2 methane nitrogen air 0 01 to 100 Nm 3 h 1 to 8 bara

    Original URL path: http://ms2-engineering.de/e_produkte_bsp_komp.htm (2016-02-12)
    Open archived version from archive


  • pressure changes The verifiable leakage rate of testing devices with small volume lies under industrial conditions at approx 10 5 Pa m 3 s The detection limit sinks drastically with major volume Further more the metering precision is being reduced by changes of temperature and flexible deformations of the testing device Leakage test with test gas method With this method smaller leakages can be detected readily This method keeps the testing devices dry Nowadays for this method several gases are being used The preferred gases used were helium and hydrogen back Map of the usual leakage testing methods and their detection limits a leak test with the bubble Test gas Principle smallest leakage rate Air The pressurized test device is submerged completely into the test liquid When bubbles occur a leakage is detected 10 4 Pa m 3 s Air The surface of the test device is covered with a Tensid The pressure in the test device will raise leakages will be showen by foam bubble 10 4 Pa m 3 s b Leakage test with change of pressure Test gas Principle smallest leakage rate Air The test device will be pressurized and locked The decrease of pressure will be measured over a specific period à Temperature change effects the result 10 5 Pa m 3 s dependent on volume and test time Air The test device will be evacuated and locked The increase of pressure will be over a specific period à Temperature change effects the result 10 5 Pa m 3 s dependent on volume and test time Air Pressure differential will be created between test device and environment The gas flow needed to keep the difference of pressure constant will be measured 10 4 Pa m 3 s Air The test device will be pressurized or evacuated

    Original URL path: http://ms2-engineering.de/e_produkte_leckage.htm (2016-02-12)
    Open archived version from archive


  • can offer you a noncommittal proposal You will be surprised which potentials lie in a revision of the test bench and the automation concept MS2 maintenance service A shutdown of a test bench is expensive To prevent this we offer you a coordinated maintenance concept Uncomplicated and fast Test benches are usually technically very complex Their optimal availability is assured either on the spot or by remote diagnostic by our