archive-de.com » DE » B » BEITZKE.DE

Total: 59

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • System Integration Beitzke | References | Energy consultancy
    oil boiler distribution pumps expansion tank radiators with preadjustable thermostatic valves Design of hot water system Design of solar system 8m Design of utilisation of rainwater 10 m³ Design of electrical distribution General energy saving advice 2003 Special features No data are available from the time before renovation in 1995 Within the scope of the renovation a new oil fired heating system with a 22kW low temperature boiler was installed A standard solar system was added in 9 1998 Roof inclination 72 orientiation 25 8 5 m flat collector Solartop FK 2000 Warm water tank 300 litres Cover rate 63 Efficiency 25 Specific annual collector output 242 kWh m Calculated potential oil saving 290 9 liters The year 2004 was used for optimisation The burner output was reduced to 16kW an oil counter installed the boiler efficiency enhanced chimney heat recuperation system CHRS installed solar tank extended following leaking problems solar control renewed heat consumers hydraulically balanced Calculated with GetSolar Solar tank extended and connected in series with 400 litres extra Cover rate75 Efficiency 30 Spezific annual collektor gain 288 kWh m Calculated potential oil saving 345 6 litres Consumption data Climate corrected consumption forecast to 2007 Year Mean of

    Original URL path: http://www.beitzke.de/en/ref/jung.html (2016-02-08)
    Open archived version from archive


  • System Integration Beitzke | References | Energy consultancy
    of air quantity from 3 air conditioning systems according to the requirements of the tenants Recalculation of air washer performance Drop separator of air washers improved Hygiene of air washers brought up standard To achieve an almost draft free office environment the air outlets were modified and adjusted Hydraulic adjustment of heating distribution Equilibration of static heating and heat output of the air conditioning system To compensate the solar heating of west side of the building special control measures were executed Improved control of the water chiller refac 4 step control Energy performance of condensors technically improved Modification of switching cabinets adaptation of all controls stäfa Energy optimisation by raising detailed schedule for servicing air condition heating ventilation cooling Modification of waste water lifting system basement level with discotheque rooms Restaurant area reactive current compensator installed General energy saving advice Special circumstances By exactly timing all systems to the users requirements we were able to reduce the annual cost of running the air conditoning system alone by 5 000 euros With preventive maintenance tailored to the system technology the error free running of 99 5 was achieved To ensure that the water in the washers of the due point adjusted

    Original URL path: http://www.beitzke.de/en/ref/blondel.html (2016-02-08)
    Open archived version from archive

  • System Integration Beitzke | Problems?
    privilege to deal with wonderful challenges presented to us in the guise of insoluble problems John Gardner Entrance Exit About us Page written 19 12 1998 last update 17 44

    Original URL path: http://www.beitzke.de/en/dbphrase.html (2016-02-08)
    Open archived version from archive



  •