  • System Integration Beitzke | Service for heating and air-conditioning
    spend You will be invoiced accordingly The reality is that every day we get a large number of mails containing inquiries and request for consultation so many in fact that these would take up all of our time We are therefore not able to spend 24 hours of the day providing free mail answers with correct useful and money saving advice to everybody Consulting via telephone is also possible if you send a short mail in advance and will be charged per minute We can normally offer you energy saving options Because of the risk of virus we are obliged to delete mails with attachments which we are not expecting at the server On the spot consulting and implementation Take advantage of our unique combined knowledge in the fields of our plant engineering control and computer technology We are on call to help you on site with expert advice and options for remedial action We are specialized in trouble shooting and can implement innovative and energy saving concepts Our special interest is solving tasks where others have failed We can beat your problem Up to now our analysis has improved every system we have looked at We have never left

    Original URL path: http://www.beitzke.de/en/service.html (2016-02-08)
    Open archived version from archive


  • System Integration Beitzke | Energy Consultancy | www.beitzke.de
    as it was meant to We can offer the following range of remedies Fault finding Increase of efficiency Energy saving consultancy Heating systems Air conditioning Ventilation systems Electrical engineering Systems control technology Measurement and data gathering Networking PC installation All information on these pages has been carefully compiled However there may be unintentional errors for which we cannot accept any legal responsibility or liability under any circumstances In most cases

    Original URL path: http://www.beitzke.de/en/about.html (2016-02-08)
    Open archived version from archive

  • System Integration Beitzke | Server statistics
    on these pages has been carefully compiled and updated permanently However there may be unintentional errors for which we cannot accept any legal responsibility or liability under any circumstances In most cases the names of software and hardware mentioned are registered trademarks and subject to current regulations We will be pleased to receive constructive ideas which can help us to improve the quality of information on these pages Entrance Exit

    Original URL path: http://www.beitzke.de/en/statistic.html (2016-02-08)
    Open archived version from archive

  • System Integration Beitzke | References | Energy consultancy
    floor heating system which could not be adjusted hydraulically Energy saving was achieved in the heating system of the conference building by hydraulic adjustments and control measures The hot water system has now a special control and can supply 12 showers even though the hot water tank is still too small Special circumstances On the ground floor of the old mill property underfloor heating installed radiators in the upper floors The energy saving table for the 3 houses around the inner yard Year OT C No degree days liters year normalized over 10 years 1995 11 3 3345 20454 20582 41 1996 9 3 3948 21884 18675 94 1997 11 1 3295 21721 22189 04 1998 11 0 3285 18111 18557 57 1999 11 6 3209 15590 16352 74 2000 11 6 3049 16109 17783 83 2001 11 0 3337 15600 15735 57 2002 11 6 3094 15760 17145 49 total mean 18153 63 18375 57 What was the effect of the remedial action Long term savings of about 1022 Euro for liquid gas every year 1995 1997 Mean values before remedial action 21353 00 20476 46 1998 2002 Mean values after remedial action 16234 00 17115 04 Savings 23

    Original URL path: http://www.beitzke.de/en/ref/oberm.html (2016-02-08)
    Open archived version from archive

  • System Integration Beitzke | Mailaddress
    of your mailing program HTML Mails Please don t send us HTML Mails Our spam protection filters them out an sends them unread to the waste paper basket Back To return to the site you were previously at press the

    Original URL path: http://www.beitzke.de/en/email.html (2016-02-08)
    Open archived version from archive

  • System Integration Beitzke | Referenzen | Energieberater
    Überströmventil Bodenheizung 3 Steigestränge 11 Verteiler kein hydraulischer Abgleich keine Sommerabschaltung Über Wärmezähler nachweisbarer Jahresnutzungsgrade der Anlage Daten sk Durchgeführte Arbeiten Wärmebedarf mit Hüllflächenverfahren und über den durch Wärmezähler nachweisbaren Jahresnutzungsgrad kontrolliert 30kW Planung auf kondensierende energiesparende Niedertemperaturanlage Kessel Verteilung Bodenheizung Hydraulischer Abgleich berechnet und durchgeführt Als einziges Bauteil wurde die Pumpe weiterverendet Steuerung Standard Bajorath Regler Umbau 2 Tage Abgleich 1 Monat Ansicht alte Atmo Anlage Klick neue Anlage Fotos db Besonderheiten Beste Voraussetzungen für eine effektive und sparsame Beheizung die Bodenheizung Durch den schlechten Nutzungsgrad entstanden allein in den Jahren 2003 bis 2007 vermeidbare Mehrkosten von ca 7900 Euro Erst nach dem Umbau war es möglich die Systemtemperaturen 45 30 C wirklich zu nutzen Dabei stellten sich wie in jedem Objekt der hydraulische Abgleich als schwierig heraus Die Wohnzimmerkreise haben gegenüber dem Rest einen sehr hohen Widerstand weil dort ein Kreis eingespart wurde Das erschwerte den hydraulischen Abgleich enorm Zeit Verbrauchsdaten Klimakorrigierter Mittelwert vor Umbau bis 2007 125 kWh m² a Verluste von ca 1583 a Mitte 2008 Umbau Klimakorrigierter Mittelwert nach Umbau 2008 2009 88 kWh m² a Verluste von ca 80 a 2009 wurde ein Jahresnutzungsgrad von 96 erreicht mit einem Kessel der einen Normnutzungsgrad von

    Original URL path: http://www.beitzke.de/de/ref/seidenw.html (2016-02-08)
    Open archived version from archive

  • System Integration Beitzke | Referenzen | Energieberater
    25 Funktionsweise Durch die solare Aufheizung der Dachbedeckung entsteht eine höhere Temperatur im Deckenzwischenraum Die heiße leichtere Luft wird oben über die horizontalen Lamellen Louvers ins Freie geführt Wegen des Druckausgleichs strömt die Innenluft aus den Büros nach Dazu sind die Lüftungsgitter im Wand Decken Bereich Mehr Infos zu diesem Projekt nachhaltiges Bauen in den Tropen Innenansicht Lüftungsgitter als Band in der Decke Foto gl Ölmühle Serendipol in Sri Lanka

    Original URL path: http://www.beitzke.de/de/ref/serendipol.html (2016-02-08)
    Open archived version from archive

  • System Integration Beitzke | Referenzen | Energieberater
    alle zufrieden gerne auf Anfrage Ansicht alte Vaillant Anlage Klick neue Anlage Fotos db Besonderheiten Extrem hoher Verbrauch in den letzten Jahren u a durch VGH Warmwasser Bereiter Messwerterfassung installiert Tagesberichte als pdf im Zip zum Herunterladen Verbrauchsdaten aus der Planung vor dem Umbau Klimakorrigierter Mittelwert vor Umbau 141 8 kWh m a Klimakorrigierter Mittelwert nach Umbau 70 7 kWh m a Errechnet für 2006 13500 kWh erreicht 2006 13460

    Original URL path: http://www.beitzke.de/de/ref/quellw.html (2016-02-08)
    Open archived version from archive



  •